The CCS machine ASTM D5293 engine oil (CCS) or Cold Crank Simulator is used to determine the oil viscosity in cold and -5 to -35 degrees in various types of engine oil. The CCS device is in accordance with ASTM D5293 standard.
Viscosity measurements are required for each condition monitoring (CM) software. One of the basic properties of oil is viscosity. Changing the viscosity is very dangerous for the car and causes serious damage. Because viscosity varies greatly with temperature, the tools used to measure viscosity must take this parameter into account in viscosity calculations.
For this purpose, more viscometers ( viscometer ) must maintain a constant temperature oil tested. It is generally used to measure viscosities of 40 degrees and 100 degrees. Conventional devices have an oil bath in which the temperature of this oil is fixed at one of the above temperatures (with an accuracy of 0.01 degrees).
To measure, the test oil is poured into capillary tubes in the oil bath and the time of movement of the oil is measured at a certain distance and the viscosity of the oil is calculated using equations or control tables.
To accurately measure viscosity, the oil must first be filtered so that the used oil particles do not clog the capillary tubes and affect the oil transfer rate. It is also necessary to rinse the capillary tube well after each test so that the remaining oil has no effect on the measurement. As can be seen, measuring viscosity in this way requires a lot of time and high accuracy.
One thing to keep in mind is that the purpose of monitoring the situation should not be forgotten. The main purpose of monitoring is not to measure the viscosity of the oil, but to compare the viscosity of the oil with the previously measured values.
The purpose is not to measure viscosity, but to look for changes in viscosity. This is an important point to keep in mind when working with laboratories. The purpose of the viscosity measurement workshop is to observe changes in previous measurements. So if the goal is not to really measure the viscosity of the oil, we can use simpler equipment for this test.
ccs is designed and built with the same idea. In this instrument, the viscosity of the test oil is compared with the reference oil. Because these two oils are used for measurement and comparison, the effect of temperature on these oils is very similar. Therefore, to measure the viscosity, there is no need to stabilize the temperature properly and the reference oil can be selected to measure the viscosity at 40 ° C at ambient temperature (300 ° C).
ccs has two tubes, one of which contains reference oil. This oil is a special oil that is prepared by the manufacturer and the consumer can not reach it. The second tube looks like a syringe and draws the test oil into it like a syringe.
There is a small wire inside the pipes. The size of the bullet makes it easy to move inside the tube. After applying the test oil to the second tube, hold the instrument with the lead in the zero position to measure the viscosity. Then place the device horizontally, and gently lift the tip of the device 25 degrees. The bullets start moving.
When each bullet reaches the end of the tube, rotate the device horizontally and the other bullet reads the viscosity of the oil in centimeters from the ruler in front of it.
The accuracy of this device is less than 3%. This value allows the viscometer to be used to monitor conditions. Because monitoring the change in viscosity up to 5% is often not enough for action.
For example, if the viscosity of unused oil is 100 and the viscosity of used oil is 95, then this measurement does not yet require any practical action.
The CCS device is fully automatic and has a touch screen.
This machine is used in oil and grease laboratory, oil and gas laboratory, petrochemical laboratory, refineries, standard laboratories and research laboratories.
Daneshvar Shimi Company is an importer of oil and gas laboratory equipment and oil and gas laboratory equipment, oil and grease laboratory equipment, oil and grease laboratory equipment and related chemicals. Daneshvar Shimi Company also has the ability to supply spare parts for laboratory equipment and laboratory devices purchased by centers that have problems.
Application: Petroleum and Petrochemical Laboratory
To measure sulfur (sulfur)
Used in petroleum products.
Application: Petroleum and Petrochemical Laboratory
To distill petroleum products in
Used petroleum products.
Application: Petroleum and Petrochemical Laboratory
To measure viscosity
Kinematics in petroleum products
Application: Oil and Gasoline Laboratory
Octane gauge to measure octane
Gasoline is used.
Application: Oil and grease laboratory
Used to measure the shear stability test of engine oil.
Application: Oil and grease laboratory
Used for the apparent viscosity of oil in cold.
Application: Oil and grease laboratory
Used to measure engine oil evaporation loss.
Application: Oil and grease laboratory
Used for oil viscosity in cold pumping.
Application: Oil and grease laboratory
To measure oil viscosity at high temperature and high cutting speed
Application: Oil and grease laboratory
For analysis of oil elements according to ASTM D6595
Application: Oil and grease laboratory
To measure oil viscosity at low temperature and high cutting speed
Application: Oil and grease laboratory
Used to count suspended particles in oil.
Application: Oil and grease laboratory
To measure the number of oil distillations at a temperature of 400 degrees under vacuum
Application: Oil and grease laboratory
To measure the foam of engine oils and lubricants at high temperatures
Application: Oil and grease laboratory
To separate water and sediments from oils and petroleum products
Application: Oil and grease laboratory
Oil is used to measure mercaptan sulfur
Application: Oil and grease laboratory
To measure oil volatility test by chromatographic method
Application: Oil and grease laboratory
To measure the foam of engine oils and lubricants at high temperatures
Application: Oil and grease laboratory
Used to measure the melting point of oil and grease
Application: Oil and grease laboratory
1 to 8 are used to measure the color of the oil
Application: Oil and grease laboratory
To test the coefficient of friction and abrasion resistance of grease
Application: Oil and grease laboratory
To test the grease load capacity at high pressure
Application: Oil and grease laboratory
Used for oil and grease washing test
Application: Oil and grease laboratory
Used to test the permeability of grease and oil
Application: Oil and grease laboratory
To determine the acidic number of TAN and TBN base in oils
Application: Oil and Oil Laboratory
Carl Fisher device for measuring water in petroleum products.
Application: Oil and Oil Laboratory
To measure heavy and volatile metal elements in petroleum products
Application: Oil and Oil Laboratory
This device is used to determine the color of petroleum products.
Application: Petroleum and Petrochemical Laboratory
To measure the calorific value of petroleum products
Application: Petroleum and Petrochemical Laboratory
Used to measure the density of petroleum products.
Application: Petroleum and Petrochemical Laboratory
Used to measure the pour point and cloud of petroleum products.
Application: Oil and Gasoline Laboratory
Used to measure the step in gasoline.
Application: Petroleum and Petrochemical Laboratory
Used to measure the freezing point of petroleum products
Application: Petroleum and Petrochemical Laboratory
To measure the degree of corrosion of copper due to petroleum products
Application: Petroleum and Petrochemical Laboratory
Used to measure the amount of salt in crude oil.
Application: Petroleum and Petrochemical Laboratory
To measure the oxidation stability of gasoline
Application: Petroleum and Petrochemical Laboratory
Used to measure the aniline point of petroleum products
Application: Petroleum and Petrochemical Laboratory
Used to measure the vapor pressure of petroleum products
Application: Petroleum and Petrochemical Laboratory
To measure the brix and refractive index of petroleum products and oils
Application: Petroleum and Petrochemical Laboratory
Used to test for carbon residues in petroleum products
Email : info@d-chemi.com